use strict;
use warnings;
-use mro 'c3';
-use base qw/
- DBIx::Class::Storage::DBI::Sybase::Base
- DBIx::Class::Storage::DBI
-/;
-use Carp::Clan qw/^DBIx::Class/;
+use Try::Tiny;
+use namespace::clean;
-=head1 NAME
-
-DBIx::Class::Storage::DBI::Sybase - Storage::DBI subclass for Sybase
+use base qw/DBIx::Class::Storage::DBI/;
-=head1 SYNOPSIS
+=head1 NAME
-This subclass supports L<DBD::Sybase> for real Sybase databases. If you are
-using an MSSQL database via L<DBD::Sybase>, your storage will be reblessed to
-L<DBIx::Class::Storage::DBI::Sybase::Microsoft_SQL_Server>.
+DBIx::Class::Storage::DBI::Sybase - Base class for drivers using
+L<DBD::Sybase>
=head1 DESCRIPTION
-If your version of Sybase does not support placeholders, then your storage
-will be reblessed to L<DBIx::Class::Storage::DBI::Sybase::NoBindVars>. You can
-also enable that driver explicitly, see the documentation for more details.
-
-With this driver there is unfortunately no way to get the C<last_insert_id>
-without doing a C<select max(col)>.
-
-But your queries will be cached.
-
-A recommended L<DBIx::Class::Storage::DBI/connect_info> settings:
-
- on_connect_call => [['datetime_setup'], [blob_setup => log_on_update => 0]]
+This is the base class/dispatcher for Storage's designed to work with
+L<DBD::Sybase>
=head1 METHODS
=cut
-__PACKAGE__->mk_group_accessors('simple' =>
- qw/_blob_log_on_update/
-);
-
sub _rebless {
my $self = shift;
- if (ref($self) eq 'DBIx::Class::Storage::DBI::Sybase') {
- my $dbtype = eval {
- @{$self->dbh->selectrow_arrayref(qq{sp_server_info \@attribute_id=1})}[2]
- } || '';
+ my $dbtype;
+ try {
+ $dbtype = @{$self->_get_dbh->selectrow_arrayref(qq{sp_server_info \@attribute_id=1})}[2]
+ } catch {
+ $self->throw_exception("Unable to estable connection to determine database type: $_")
+ };
- my $exception = $@;
+ if ($dbtype) {
$dbtype =~ s/\W/_/gi;
- my $subclass = "DBIx::Class::Storage::DBI::Sybase::${dbtype}";
- if (!$exception && $dbtype && $self->load_optional_class($subclass)) {
+ # saner class name
+ $dbtype = 'ASE' if $dbtype eq 'SQL_Server';
+
+ my $subclass = __PACKAGE__ . "::$dbtype";
+ if ($self->load_optional_class($subclass)) {
bless $self, $subclass;
$self->_rebless;
- } else {
- # real Sybase
- if (not $self->dbh->{syb_dynamic_supported}) {
- $self->ensure_class_loaded('DBIx::Class::Storage::DBI::Sybase::NoBindVars');
- bless $self, 'DBIx::Class::Storage::DBI::Sybase::NoBindVars';
- $self->_rebless;
- }
}
}
}
-=head2 connect_call_blob_setup
-
-Used as:
-
- on_connect_call => [ [ blob_setup => log_on_update => 0 ] ]
-
-Does C<< $dbh->{syb_binary_images} = 1; >> to return C<IMAGE> data as raw binary
-instead of as a hex string.
-
-Recommended.
-
-Also sets the C<log_on_update> value for blob write operations. The default is
-C<1>, but C<0> is better if your database is configured for it.
+sub _ping {
+ my $self = shift;
-See
-L<DBD::Sybase/Handling_IMAGE/TEXT_data_with_syb_ct_get_data()/syb_ct_send_data()>.
+ my $dbh = $self->_dbh or return 0;
-=cut
+ local $dbh->{RaiseError} = 1;
+ local $dbh->{PrintError} = 0;
-sub connect_call_blob_setup {
- my $self = shift;
- my %args = @_;
- my $dbh = $self->_dbh;
- $dbh->{syb_binary_images} = 1;
+ if ($dbh->{syb_no_child_con}) {
+# if extra connections are not allowed, then ->ping is reliable
+ return try { $dbh->ping } catch { 0; };
+ }
- $self->_blob_log_on_update($args{log_on_update})
- if exists $args{log_on_update};
+ return try {
+# XXX if the main connection goes stale, does opening another for this statement
+# really determine anything?
+ $dbh->do('select 1');
+ 1;
+ } catch {
+ 0;
+ };
}
-sub _is_lob_type {
+sub _set_max_connect {
my $self = shift;
- shift =~ /(?:text|image|lob|bytea|binary)/i;
-}
-
-sub insert {
- my ($self, $source, $to_insert) = splice @_, 0, 3;
+ my $val = shift || 256;
- my $blob_cols = $self->_remove_blob_cols($source, $to_insert);
+ my $dsn = $self->_dbi_connect_info->[0];
- my $updated_cols = $self->next::method($source, $to_insert, @_);
+ return if ref($dsn) eq 'CODE';
- $self->_update_blobs($source, $blob_cols, $to_insert) if %$blob_cols;
-
- return $updated_cols;
-}
-
-#sub update {
-# my ($self, $source) = splice @_, 0, 2;
-# my ($fields) = @_;
-#
-# my $blob_cols = $self->_remove_blob_cols($source, $fields);
-#
-# my @res = 1;
-#
-# if (%$fields) {
-# if (wantarray) {
-# @res = $self->next::method($source, @_);
-# } else {
-# $res[0] = $self->next::method($source, @_);
-# }
-# }
-#
-# $self->_update_blobs($source, $blob_cols, $fields) if %$blob_cols;
-#
-# return wantarray ? @res : $res[0];
-#}
-
-sub _remove_blob_cols {
- my ($self, $source, $fields) = @_;
-
- my %blob_cols;
-
- for my $col (keys %$fields) {
- $blob_cols{$col} = delete $fields->{$col}
- if $self->_is_lob_type($source->column_info($col)->{data_type});
+ if ($dsn !~ /maxConnect=/) {
+ $self->_dbi_connect_info->[0] = "$dsn;maxConnect=$val";
+ my $connected = defined $self->_dbh;
+ $self->disconnect;
+ $self->ensure_connected if $connected;
}
-
- return \%blob_cols;
}
-sub _update_blobs {
- my ($self, $source, $blob_cols, $inserted) = @_;
- my $dbh = $self->dbh;
-
- my $table = $source->from;
-
- my (@primary_cols) = $source->primary_columns;
+=head2 using_freetds
- croak "Cannot update TEXT/IMAGE without a primary key!"
- unless @primary_cols;
+Whether or not L<DBD::Sybase> was compiled against FreeTDS. If false, it means
+the Sybase OpenClient libraries were used.
- my $search_cond = join ',' => map "$_ = ?", @primary_cols;
-
- for my $col (keys %$blob_cols) {
- my $blob = $blob_cols->{$col};
-
-# First update to empty string in case it's NULL, can't update a NULL blob using
-# the API.
- my $sth = $dbh->prepare_cached(
- qq{update $table set $col = '' where $search_cond}
- );
- $sth->execute(map $inserted->{$_}, @primary_cols) or die $sth->errstr;
- $sth->finish;
-
- $sth = $dbh->prepare_cached(
- "select $col from $table where $search_cond"
- );
- $sth->execute(map $inserted->{$_}, @primary_cols);
-
- eval {
- while ($sth->fetch) {
- $sth->func('CS_GET', 1, 'ct_data_info') or die $sth->errstr;
- }
- $sth->func('ct_prepare_send') or die $sth->errstr;
-
- my $log_on_update = $self->_blob_log_on_update;
- $log_on_update = 1 if not defined $log_on_update;
-
- $sth->func('CS_SET', 1, {
- total_txtlen => length($blob),
- log_on_update => $log_on_update
- }, 'ct_data_info') or die $sth->errstr;
+=cut
- $sth->func($blob, length($blob), 'ct_send_data') or die $sth->errstr;
+sub using_freetds {
+ my $self = shift;
- $sth->func('ct_finish_send') or die $sth->errstr;
- };
- my $exception = $@;
- $sth->finish;
- croak $exception if $exception;
- }
+ return $self->_get_dbh->{syb_oc_version} =~ /freetds/i;
}
-=head2 connect_call_datetime_setup
-
-Used as:
-
- on_connect_call => 'datetime_setup'
+=head2 set_textsize
-In L<DBIx::Class::Storage::DBI/connect_info> to set:
+When using FreeTDS and/or MSSQL, C<< $dbh->{LongReadLen} >> is not available,
+use this function instead. It does:
- $dbh->syb_date_fmt('ISO_strict'); # output fmt: 2004-08-21T14:36:48.080Z
- $dbh->do('set dateformat mdy'); # input fmt: 08/13/1979 18:08:55.080
+ $dbh->do("SET TEXTSIZE $bytes");
-On connection for use with L<DBIx::Class::InflateColumn::DateTime>, using
-L<DateTime::Format::Sybase>, which you will need to install.
-
-This works for both C<DATETIME> and C<SMALLDATETIME> columns, although
-C<SMALLDATETIME> columns only have minute precision.
+Takes the number of bytes, or uses the C<LongReadLen> value from your
+L<connect_info|DBIx::Class::Storage::DBI/connect_info> if omitted, lastly falls
+back to the C<32768> which is the L<DBD::Sybase> default.
=cut
-{
- my $old_dbd_warned = 0;
-
- sub connect_call_datetime_setup {
- my $self = shift;
- my $dbh = $self->_dbh;
-
- if ($dbh->can('syb_date_fmt')) {
- $dbh->syb_date_fmt('ISO_strict');
- } elsif (not $old_dbd_warned) {
- carp "Your DBD::Sybase is too old to support ".
- "DBIx::Class::InflateColumn::DateTime, please upgrade!";
- $old_dbd_warned = 1;
- }
-
- $dbh->do('set dateformat mdy');
-
- 1;
- }
-}
-
-sub datetime_parser_type { "DateTime::Format::Sybase" }
+sub set_textsize {
+ my $self = shift;
+ my $text_size =
+ shift
+ ||
+ try { $self->_dbi_connect_info->[-1]->{LongReadLen} }
+ ||
+ 32768; # the DBD::Sybase default
-sub _dbh_last_insert_id {
- my ($self, $dbh, $source, $col) = @_;
+ return unless defined $text_size;
- # sorry, there's no other way!
- my $sth = $dbh->prepare_cached("select max($col) from ".$source->from);
- return ($dbh->selectrow_array($sth))[0];
+ $self->_dbh->do("SET TEXTSIZE $text_size");
}
1;
-=head1 DATES
-
-See L</connect_call_datetime_setup> to setup date formats
-for L<DBIx::Class::InflateColumn::DateTime>.
-
-=head1 IMAGE AND TEXT COLUMNS
-
-See L</connect_call_blob_setup> for a L<DBIx::Class::Storage::DBI/connect_info>
-setting you need to work with C<IMAGE> columns.
-
-Due to limitations in L<DBD::Sybase> and this driver, it is only possible to
-select one C<TEXT> or C<IMAGE> column at a time.
-
=head1 AUTHORS
See L<DBIx::Class/CONTRIBUTORS>.
You may distribute this code under the same terms as Perl itself.
=cut
-# vim:sts=2 sw=2: